Calculation of filtration area
Calculation of filtration area
Q:flow (m3/s)
U: dynamic viscosity (pa.s)
A: area (㎡)
K:Oil capacity coefficient (m3/㎡)
Wire mesh filter element K=0.34
Wedge wire filter element K=0.17
Paper filter element K=0.006
1. Metal felt filtration area
u: dynamic viscosity (Pa.s)
Q: flow (m3/s)
ΔP: pressure difference (pa)
H: height (m)
K:penetrability coefficient (㎡)
2. Area is calculated according to the standard flow rate of filter element
a. resin filter:water 0.15bar 10 inch.
5μm 10L/ min
10μm 18L/min
25μm 30L/min
b. Wedge wire filter element: water ΔP=0.15bar 10 inch
1μm 8 L/ min
5μm 20 L/ min
10μm 32L/min
25μm 38L/min
c. Melt-blown filter element:water ΔP=0.15bar 10 inch
1μm 4.5L/ min
5μm 9 L/ min
10μm 14L/min
20μm 18L/min
The calculated area is the flow data in the pure state, and it should be considered to increase the appropriate area to extend the service cycle, generally at least one or two times, or even four times.
The above method just for reference.